Steel consumer unit with a pre-wired 100 A double-pole isolator as a main switch. 2 outgoing ways: room for 1 double-pole RCBO. For a shore power AC-in board when you want a separate main switch. Surface mount, IP20, white powder-coated steel; knockouts for M25, M32 and M40 glands.
230 V can kill. Get it signed off.
A mistake on the 230 V side can cause a fatal electric shock or a fire, and it often looks fine until something fails. Every 230 V installation must be inspected, tested and signed off by a qualified electrician before it is used. Book our inspection and sign-off service (at our Cumbria workshop, with test results and a certificate).
A compact metal-clad consumer unit for a campervan, motorhome, boat or cabin mains system. The 100 A double-pole isolator is already fitted and wired, so you add one 2-module double-pole RCBO.
MCG metal consumer units are what we now fit on our own Victron panel builds, and they are the boards you will see in our latest Instagram reels. We chose them for the steel enclosure (non-combustible, as BS 7671 Amendment 3 asks for), the pre-wired double-pole isolator, and MCG double-pole 30 mA Type A RCBOs that switch both line and neutral.
The same MCG range, sold separately: 4-way, 6-way, 10-way, 14-way, compact AC-in unit, 16 A RCBO, 10 A RCBO. Fit RCBOs largest first, next to the main switch, and use Build your board to add the board, RCBOs and blanking pieces in one go, or let our system designer pick the board from what you plug in.
Watch them on our reels
MCG consumer units and RCBOs are what we fit on our panel builds, and you will see them in our recent reels.
Reel 1Reel 2Reel 3Reel 4Reel 5Reel 6Reel 7Post 8Reel 9Reel 10
The systems in our reels include Victron and other components that are not included in the price.
For most vehicles, the shore power AC-in needs only one double-pole RCBO: it gives overload, short-circuit and 30 mA earth-fault protection and switches both live and neutral. That fits our compact AC-in consumer unit, which is smaller and costs less. Choose this 2-way board when you also want a separate main switch, for example so the whole AC-in can be isolated at the board for servicing, or because your installer or insurer prefers one.
RCBOs are sold separately: our 16 A double-pole RCBO suits the hook-up supply and socket circuits, and our 10 A double-pole RCBO suits lighting or a single fixed appliance. Fill any unused ways with blanking pieces so no live parts can be touched. Not sure which cable each circuit needs? Our cable size calculator sizes the cable for each 230 V circuit. IP20 means it must sit inside a dry cupboard or locker. Mains work must be installed and tested by a competent person to BS 7671.
Free 30-minute call, Victron kit specified for your build, wiring diagram part for part.
Add the RCBO that sits beside the main switch. One 16 A RCBO is the usual choice for a shore power AC-in.
230 V can kill. Have every 230 V installation inspected, tested and signed off by a qualified electrician before you use it. Our inspection and sign-off service